Tel: 0333 1887390    sales@generator-backup.co.uk
Menu

1650kVA Mitsubishi S12R-PTAA2 Diesel Generator

Engine:
Mitsubishi
Prime:
1500kVA / 1200 kW
Standby:
1650kVA / 1320 kW
Hz:
50
Voltage:
3 Phase
Weatherproof Canopy
Auto Start Controller
Bunded Base Fuel Tank
Available Open or with Weatherproof Canopy / Container
Get a Quote / More Information
Specifications
Control System
Canopy

SPG power generation system, providing optimum performance, reliability, and versatility for stationery standby, prime power, and continuous duty applications. All generator sets are prototype tested, factory build, and production tested.

  •  High quality, reliable and complete power unit
  •  Compact design
  •  Easy start and maintenance possibility
  •  Every generating set is subject to a comprehensive test program which includes full load testing, checking and provision of control and safety shut down functions testing
  •  Fully engineered with a wide range of options and accessories : Canopy, sound proof canopy and on-road trailer

ISO8528 - This generator set has been designed to meet ISO 8528 regulation.

ISO 9001 - This generator set is manufactured in facilities certified to ISO 9001.

 This generator set is available with CE certification

Enclosed product is tested according to EU noise legislation 2000/14/EC

Dimensions and Weight

Open Type
Dimensions (LxWxH) mm 5000 x 2200 x 3100
Dry Weight kg 13000
Sound Attenuated Type
Dimensions (LxWxH) mm 9000 x 2800 x 3300/4800
Dry Weight kg 18000

Phase Rating, 50Hz, PF 0,8

Voltage Standby Rating (ESP) Prime Rating (PRP) Amp
kVA kW kVA kW
400/230 1650 1320 1500 1200 2168

Standby Rating (ESP) : Continuous running at variable load for duration of an emergency. No overload is permitted on these ratings. In accordance with ISO 3046.

Prime Rating (PRP) : Continuous running at variable load for unlimited periods with 10% overload for 1 hour in any 12 hour period. In accordance with ISO 8528, ISO 3046.

Diesel Engine Specifications

Manufacturer Mitsubishi
Model S12R-PTAA2
Engine Power Output at rated rpm kWm 1441
HP 1932
No. of Cylinders and Build 12 Cylinder V Type
Engine Speed rpm 1500
Aspiration and Cooling Turbocharged and Two Pump Two Loop
Total Displacement L 49
Bore and Stroke mm x mm 170 x 180
Compression Ratio 13,5:1
Governor Electronic
Fuel Consumption at full load L/hr 317
Fuel Tank Capacity Litre Open : 2000 / Canopy : 2200
Oil Capacity Litre 180
Coolant Capacity L 317
Radiator Cooling Air m³ /min. 1800
Air Intake - Engine m³ /min. 120
Exhaust Gas Flow m³ /min. 318
  •  Heavy duty, water cooled, Diesel engine
  •  Radiator with mechanical fan
  •  Protective grille for rotating and hot parts
  •  Electric starter and charge alternator
  •  Starting battery (with lead acid) including rack and cables
  •  Engine coolant heater
  •  Steel base frame and anti-vibration isolators
  •  Spare external fuel tank (open set)
  •  Flexible fuel connection hoses
  •  Single bearing, class H alternator
  •  Industrial exhaust silencer and steel bellows supplied separately
  •  Static battery charger
  •  Manual for application and installation

Alternator Specifications

Design Brushless 4 poles
Insulation System Class H
Rotor Single Bearing System, Flexible Disc
Exciter type Electronic (AVR)
  •  Brushless single bearing system, flexible disc, 4 poles
  •  Insulation class H
  •  Electronic (AVR)

Optional Equipment

Engine
Fuel water seperator filter
oil heater

Alternator
Anti-Condensation Heater
Over sized alternator
Main line circuit breaker
PMG excitation + AVR
Single Phase (4 lead)

Panel
Automatic synchronising and power control system (multi gen-set parallel)
Transition synchronization with mains
Remote annunciator panel
Remote relay otput
Alarm output relays
Charge ammeter
Earth fault, single set

Accessories
Automatic or manual fuel filling system
Manual oil drain pump
Low and high fuel level alarm
Residential silencer
Enclosure weather protective or sound attenuated
Duct adapter (on radiator)
Inlet and outlet accoustic baffles
Inlet and outlet motorised lourvers
Tool kit for maintenance
1500/3000 hours maintenance kit
Double wall chassis
Supplied with oil and coolant
Main Fuel Tank/p>

Control supervision and protection panel is mounted on the genset base frame. The control panel is equipped as follows:

  • 1. Auto Mains Failure Control Panel
    • Generating set control AMF module DSE 7320
    • Static battery charger
    • Emergency stop push button
  • 2. Power Outlet Terminal Board Mounted on the Gen-set Base Frame

Generating set control module DSE 6020 features

The module is used to monitor mains supply and starts and stops of a standby generating set
Micro-processor based design
Automatic control of main and generator contactors
Monitors engine performance and AC power output LED alarm indication
Front panel configuration of timers and alarm trip points
CAN and magnetic pick-up versions(specify on ordering)
4 digital inputs/3 analogue inputs
6 outputs(4 configurable on Magnetic Pick-up, 6 configurable onCANbus version)
Easy push button control STOP/RESET -MANUAL -AUTO -TEST –START

Metering via LED display

Generator Volts (L-L / L-N)
Engine oil pressure (PSI-Bar)
Generator Ampere (L1,L2,L3)
Engine temperature (°C&°F)
Generator Frequency (Hz)
Plant battery volts
Engine hours run
Mains Volts (Ph-Ph/Ph-N)

Alarms

Over and Under Speed
Low and High Battery Volt
Start and Stop Failure
Charge fail
Over Current
Under / Over Generator Voltage
Low Oil Pressure
Emergency stop
High engine temperature

LED indicators

Mains available
Generator available
Mains on load
Generator on load

  •  Compact footprint, low profile design.
  •  Enclosure, generator set, exhaust system and fuel tank are pre-assembled, pre-integrated and shipped as one package
  •  Body made from steel components treated with polyester powder coating
  •  Fire retardant foam insulation
  •  Easy access to all service points
  •  Exhaust system inside canopy
  •  Large doors on each side
  •  Control panel viewing window in a lockable access door
  •  Emergency stop push button mounted on enclosure exterior
  •  Cooling fan and battery charging alternator fully guarded
  •  Fuel fill and battery can only be reached via lockable access doors.
  •  Lifting points on the top of canopy and base frame
  •  Customer options available to meet your applications needs.
  •  Generating sets' noise level tests in accordance with directive 2000/14/EC validation of the noise level test has been approved by the noified body Szutest

For all enquiries or quotations call Tel: 0333 1887390

Contact Us
Top crossmenuchevron-down